B.2: Digital Part Numbering
952VP
0120
X
CP = Control Pulse
VP = Variable Pulse
RS = RS422 Start/Stop Pulse
Interrogation Mode (with VP only)
I = Internal Interrogation
E = External Interrogation
Stroke in Inches
Insert stroke in inches to 0.1 inch. Enter as a four-place
number. Example: 12.0 in stroke entered as 0120. To
convert a metric stroke in millimeters, multiply millimeter
value by 0.03937 to arrive at inch value.
X E
I
Null Zone
X = Standard 2 inch Null
N _= Insert non-standard Null over 2 inches
Dead Zone
X = Standard Dead Zone of 2.5 inches
D _= Insert non-standard Dead Zone over 2.5 inches
* If option E (environmental connector) is selected, mating connector
and/or pigtail must be ordered separately. NOTE 1: On unsupported stroke
lengths greater than 4 feet, rod support bracket(s) and a special magnet
should be used. NOTE 2: Specify as magnet separate line item (standard
magnet is SD0400800).
WARNING: Not for use with a GEMCO interface.
001
Recirculations Required (with VP only)
001 (standard) to 127
Connector Style
E = Environmental MS Connector*
C _= Potted Pigtail Cable Assembly. Insert Pigtail length in feet.
T = Threaded Metal Connector (ts MTS - RB on Tempo II
TM
or III) (RS and VP only)
Q = Bayonet Style Connector (ts MTS - RC on Tempo II
TM
or III) (RS and VP only)
M = 1/4 Turn Quick Disconnect (ts MTS - MS on Tempo II
TM
or III) (RS and VP only)
Seitenansicht 29