Ametek SFA Series Ethernet Programming Bedienungsanleitung Seite 45

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 159
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 44
SG Series Programming Ethernet Configuration and Remote Programming
M550129-03 Rev K
5-5
Interface differs in that its banner shows “SGA” and it does not come
with the POWER or PRESETS pages.
Figure 5-4. Power Supply’s Home Page
(SGI shown here)
5.2.2
Network Setup Using Auto-IP
For this method, use a VXI-11 compliant discovery program such as National
Instrument’s NI-VISA to discover the IP address assigned to the power
supply. The power supply will assign itself an IP address in the IP address
range from 169.254.0.1 to 169.254.255.254 with a subnet mask of
255.255.0.0.
NOTE: When connecting your Sorensen unit to a network, Elgar strongly
recommends using Linksys® hubs or switches, which have undergone
extensive compatibility testing with the Ethernet interface.
1. Start with the power supply in the power-off state.
2. Connect a crossover cable from the power supply directly to your PC.
3. If the PC is already configured to obtain an IP address automatically,
skip to Step 4. Otherwise:
a. In Windows click Start, Settings, Control Panel.
b. Click open Network Connections. (For XP, if in the Category
View, click Network and Internet Connections, and then Network
Connections).
Seitenansicht 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 158 159

Kommentare zu diesen Handbüchern

Keine Kommentare