5.1.1.1 Specific Test Limitations and Discrepancies
While every effort has been made to provide comprehensive coverage of the Mil-Std 704 tests, some
limitations apply, largely due to hardware limitations of the MX power source. The following table lists
specific implementation issues by test number. The deviation from the standard requirement is shown
in the “Actual setting” column. The reason for the deviation is shown in the last column.
.5Vp-v modulation (.3536V RMS)
3.5Vp-v modulation (2.475V RMS)
.5Vp-v modulation (.3536V RMS)
3.5Vp-v modulation (2.475V RMS)
Requires additional equipment
Requires additional equipment
Requires additional equipment
Requires additional equipment
Requires additional equipment
Requires additional equipment
Requires additional equipment
Requires additional equipment
Requires additional equipment
Dwell time = 1 cycle (16.666667 msec)
Dwell time = 1 cycle (16.666667 msec)
Dwell time = 1 cycle (16.666667 msec)
400VDC limit (test written but will not run)
Hardware limit DC range MX
400VDC limit (test written but will not run)
Hardware limit DC range MX
5.1.2 i/iX Series -704 Option Limitations
The extent of coverage of the –704 option as implemented on the IX Series platform is shown in the
table below. Tests marked with an „x‟ generally require additional hardware to be used. Tests marked
„N/A‟ are not applicable to the corresponding table. Tests marked with a „‟ are covered by at least
one rev of the MIL-STD-704. Tests marked with a „P‟ require arbitrary waveform capability, which is
available on iX models only.
Load and Current
Harmonic
Measurements