User Manual – Rev H California Instruments
Avionics Software
8.4.1.5 Table LDC:
Surge to 36V max, Sag to 18.5V min
Surge to 40V max, Sag to 17V min
Test performed in ripple window.
Test performed in ripple window.
Requires Additional Equipment
Test requires multiple load cables
Test not performed with software
Test requires multiple load cables
Test not performed with software
Voltage Variations Due to APU Starting
Start at 12.5V, ramp up to 26.5V
Per Figure 13, Appendix B
DC Ripple Voltage Due to Equipment
Requires Additional Equipment
Voltage Spike due to Equipment Load Switching
Requires Additional Equipment
Compatibility with SEPDC Voltage Clipping Devices
Requires Additional Equipment
Abnormal Voltage Transients
DO160 16.6.2.4.c and 16.6.2.3.b
Abnormal Voltage Transients
DO160 16.6.2.4.c and 16.6.2.3.b
Emergency Steady State Voltage
Test performed in ripple window.
Test requires special cables
Test not performed with software
Voltage Switching Transients 1
Voltage Switching Transients 1
Voltage Switching Transients 1
Voltage Switching Transients 1
Voltage Switching Transients 1
Voltage Switching Transients 2
Voltage Switching Transients 2