M362250-01 Rev C www.programmablepower.com
DCS-E 1kW Series,
DLM-E 3kW & 4kW
Power Supplies
M51A Option: Isolated Analog
Programming Manual
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - DLM-E 3kW & 4kW

M362250-01 Rev C www.programmablepower.com DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual

Seite 2

Contents DLM-E Series and DCS-E Series LIST OF TABLES Table 2–1. SW1 SETUP Switch...

Seite 3

SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction This manual is to be used in conjunction with the DCS-E 1kW Series & DCS-E 1.2kW Series DC Power

Seite 4

M51A Option Overview DLM-E Series and DCS-E Series 1-2 M51A Option 1.3 Specifications 1.3.1 Electrical Specifications Remote Voltage Programming A

Seite 5 - Programming Manual

SECTION 2 ISOLATED ANALOG PROGRAMMER OPERATION 2.1 SW1 Switch The SW1 SETUP switch is accessible from the rear panel of the unit. It provides user

Seite 6

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.1.1 SW1 Switch Setup The following sections describe the functions of the vari

Seite 7 - SAFETY SYMBOLS

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.2 ISOLATED ANALOG PROGRAMMER Connector (J4) The ISOLATED ANALOG PROGRAMMER co

Seite 8

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2-4 M51A Option 2.2.1 ISOLATED ANALOG PROGRAMMER Functions The following secti

Seite 9 - CONTENTS

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation M51A Option 2-5 Analog Programming Signals OVP PROGRAMMING INPUT: Pin-3, an i

Seite 10

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2-6 M51A Option Auxiliary Sources AUXILIARY DC OUTPUT: Pin-15, 16VDC source for

Seite 11 - M51A OPTION OVERVIEW

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3 Remote Programming Configuration 2.3.1 Voltage Source Programming of Outpu

Seite 13 - PROGRAMMER OPERATION

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.2 Voltage Source Programming of Output Current SW1 Switch Settings SW1-2 ON

Seite 14 - 2.1.1 SW1 Switch Setup

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.3 Voltage Source Programming of OVP SW1 Switch Settings SW1-3 ON (1) = 0–5

Seite 15 - 12 Isolated Analog Common

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.4 Resistance Programming of Output Voltage SW1 Switch Settings SW1-1 ON (1)

Seite 16

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.5 Resistance Programming of Output Current SW1 Switch Settings SW1-2 ON (1

Seite 17

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.6 Resistance Programming of OVP SW1 Switch Settings SW1-3 ON (1) = 0–5K 23

Seite 18

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.7 4-20mA Current Source Programming of Output Voltage SW1 Switch Settings

Seite 19 - 291213 1

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.8 4-20mA Current Source Programming of Output Current SW1 Switch Settings S

Seite 20 - 2101213 1

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.9 Programming the Shutdown Function 21312515+5VGND14 Figure 2–3. Using Shu

Seite 21 - 2361213 1

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.11 Shutdown Application – Contact Closure An external relay, whether normally

Seite 22

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 13 125 1514 Figure 2–5. Using Shutdown with Contact Closure of a Normally OPEN

Seite 24

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.12 Local/Remote Application An external relay or switch may be used to select

Seite 25 - 91213 12

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation M51A Option 2-19 2.4 Remote Monitoring Analog signals are available for monitor

Seite 26 - 111213 12

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2-20 M51A Option This page intentionally left blank.

Seite 28

About AMETEK AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design and manufacture of precision, programmable

Seite 29

This page intentionally left blank. ii

Seite 30

Important Safety Instructions Before applying power to the system, verify that your product is configured properly for your particular application.

Seite 31 - 2.4 Remote Monitoring

This page intentionally left blank. iv

Seite 32 - 2-20 M51A Option

CONTENTS SECTION 1 M51A OPTION OVERVIEW ............1-1 1.1 Introduction ...........