Isolated Analog Programmer Operation DLM-E Series and DCS-E Series
2.3.6 Resistance Programming of OVP
SW1 Switch Settings
SW1-3 ON (1) = 0–5K
2361213 1
25
141621
Set up for resistance programming of the output voltage as follows:
1. Set SW1-3, OVP PROG, to ON (1) for 0-5VDC programming range.
2. Connect the external programming resistance, 0-5KΩ, to the ISOLATED ANALOG
PROGRAMMER connector, from Pin-3 to Pin-12.
3. Connect a jumper from Pin-3 to Pin-21 or Pin-22, (whichever one is available) to connect
the 1mA current source.
4. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER
connector, J4, to Pin-2 to enable remote control.
5. Program the other parameters to the desired limit values.
6. Connect Pin-16, OVP Default Programming Input, of the ISOLATED ANALOG
PROGRAMMER connector (J4) to Pin-6 to disable the default OVP programming
connection.
2-12 M51A Option