Ametek DCS-E 1kW Series Programming Manual Bedienungsanleitung Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
Isolated Analog Programmer Operation DLM-E Series and DCS-E Series
2.3.8 4-20mA Current Source Programming of Output Current
SW1 Switch Settings
SW1-2 ON (1) = 4-20mA
10
4-20mA
111213 12
2
5
1423
Set up for 4-20 mA programming of the output current as follows:
1. Set SW1-2, I PROG, to ON (1) for 4-20mA programming range.
2. Connect the external programming current source to the ISOLATED ANALOG
PROGRAMMER connector, J4, with the source to Pin-10 and the return to Pin-13.
3. Connect a jumper from Pin-13 to Pin-12 to connect the 4-20mA current sense resistors
to common.
4. Connect a jumper from Pin 23 to Pin 11 to provide the negative 2.5VDC to zero out the
4mA signal generated by internal circuits.
5. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER
connector, J4, to Pin-2 to enable remote control.
6. Program the other parameters to the desired limit values.
2-14 M51A Option
Seitenansicht 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 32

Kommentare zu diesen Handbüchern

Keine Kommentare